Primary Applications
- Circulating cooling-water supply for compatible environmental test chambers and laboratory equipment.
- Removal of process heat from equipment requiring a controlled water circuit.
- Facility cooling installations where an equipment-linked air-cooled chiller is appropriate.
- Selection of water flow, tank capacity and cooling duty for the actual heat load and ambient conditions.
Product Features
- Current WB-B series: 12 listed models with nominal cooling capacities from 20 to 124 kW.
- Air-cooled refrigeration with a circulating chilled-water supply.
- Model-specific water flow, tank volume, installed power and maximum current are listed separately.
- Closed-loop water circulation helps protect circuit cleanliness.
- Legacy MLS-ZKSL GTS data remain separately identified and are not mixed with the WB-B series.
Applicable Safety Standards
Review the applicable equipment-safety and refrigeration requirements for the supplied chiller and its installation.
General equipment-safety reference for laboratory, measurement and control equipment.
Define in your protocol
- Equipment scope, supply and intended installation
- Applicable edition, risk assessment and documentation
Confirm for this chamber
- Electrical and temperature-related protective measures
- Required conformity assessment for the supplied equipment
Refrigerating-equipment safety reference, where the equipment falls within its scope.
Define in your protocol
- Equipment classification and intended operating conditions
- Refrigerant, installation environment and protective measures
Confirm for this chamber
- Refrigeration circuit, pressure protection and service access
- Required design review and conformity documentation
Refrigeration-system classification and safety/environmental selection criteria for project review.
Define in your protocol
- System classification, refrigerant and occupancy category
- Applicable published amendments and installation requirements
Confirm for this chamber
- Refrigerant charge, room conditions and project safeguards
- Required documentation and responsibility for the installation
Related Industry Requirements
Safety & utility requirements
Equipment-linked chilled-water supply
Match the process heat load, water temperature, flow, ambient conditions and installation utilities to the connected equipment. Review the applicable equipment-safety and refrigeration references above; these are not specimen environmental-test methods.
Safety & utility requirements
Equipment-linked chilled-water supply
Match the process heat load, water temperature, flow, ambient conditions and installation utilities to the connected equipment. Review the applicable equipment-safety and refrigeration references above; these are not specimen environmental-test methods.
Safety & utility requirements
Equipment-linked chilled-water supply
Match the process heat load, water temperature, flow, ambient conditions and installation utilities to the connected equipment. Review the applicable equipment-safety and refrigeration references above; these are not specimen environmental-test methods.
These are equipment-safety and refrigeration-system references for specification review, rather than specimen environmental-test methods. Required conformity documentation and design criteria are agreed for the supplied system. The applicable edition, test severity, load and monitoring requirements are confirmed for the ordered configuration. Standard references do not imply complete product certification.
Technical Specifications
| Main Technical Specifications | ||||
|---|---|---|---|---|
| Model | WB-B48C-F | WB-B58C-F | WB-B76C-F | |
| Nominal class | 6 HP | 7.5 HP | 10 HP | |
| Cooling-air flow | m³/h | 9900 | 14300 | 14300 |
| Cooling capacity | kW | 20 | 24 | 32 |
| Chilled-water flow | m³/h | 3.6 | 5 | 7.2 |
| Power supply | 380V 50Hz | |||
| Water tank capacity | L | 200 | 360 | 360 |
| Installed power | As listed | 6 kW | 8.5 kW | 10.5 kW |
| Maximum current | A | 14 | 19.5 | 24.5 |
| Cable cross-section | mm² | 4 | 4 | 6 |
| Supply circuit breaker | A | 25 | 25 | 32 |
| Unit weight | kg | 260 | 290 | 360 |
| Operating weight | kg | 480 | 670 | 740 |
| Overall dimensions | L × W × H (mm) | 1300 × 800 × 1600 | 1550 × 900 × 1600 | 1550 × 900 × 1600 |
Legacy MLS-ZKSL GTS specifications
| Main Technical Specifications | |||
|---|---|---|---|
| MLS-ZKSL02GTS – MLS-ZKSL05GTS | |||
| Model | MLS-ZKSL02GTS | MLS-ZKSL03GTS | MLS-ZKSL05GTS |
| Cooling-air flow (m³/h) | 2200 | 3300 | 5500 |
| Cooling capacity (kW) | 6 | 9 | 15 |
| Chilled-water flow (m³/h) | 1.5 | 2.5 | 3.6 |
| Power supply | 220 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz |
| Water tank capacity (L) | 25 | 40 | 70 |
| Installed power | 2 kW | 3 kW | 5 kW |
| Maximum current (A) | 5 | 7.2 | 14 |
| Cable cross-section (mm²) | 2.5 | 2.5 | 4 |
| Circuit breaker (A) | 10 | 16 | 20 |
| Pump power / head | 0.55 kW / 25 m | 0.75 kW / 25 m | 0.75 kW / 25 m |
| Unit weight (kg) | 70 | 130 | 190 |
| Operating weight (kg) | 100 | 200 | 300 |
| Overall dimensions · L × W × H (mm) | 690 × 790 × 1200 | 800 × 690 × 1200 | 960 × 790 × 1300 |
| Main Technical Specifications | ||||
|---|---|---|---|---|
| Model | WB-B88C-F | WB-B95C-F | WB-B114C-F | |
| Nominal class | 12 HP | 15 HP | 18 HP | |
| Cooling-air flow | m³/h | 20800 | 22600 | 22600 |
| Cooling capacity | kW | 37 | 41 | 49 |
| Chilled-water flow | m³/h | 7.2 | 10 | 10 |
| Power supply | 380V 50Hz | |||
| Water tank capacity | L | 360 | 500 | 500 |
| Installed power | As listed | 12 kW | 13 kW | 14.5 kW |
| Maximum current | A | 28 | 33 | 39 |
| Cable cross-section | mm² | 6 | 6 | 10 |
| Supply circuit breaker | A | 32 | 40 | 50 |
| Unit weight | kg | 390 | 550 | 610 |
| Operating weight | kg | 770 | 1080 | 1140 |
| Overall dimensions | L × W × H (mm) | 1650 × 950 × 2000 | 1850 × 1050 × 2000 | 1850 × 1050 × 2000 |
Legacy MLS-ZKSL GTS specifications
| Main Technical Specifications | ||||
|---|---|---|---|---|
| MLS-ZKSL06GTS – MLS-ZKSL12GTS | ||||
| Model | MLS-ZKSL06GTS | MLS-ZKSL08GTS | MLS-ZKSL10GTS | MLS-ZKSL12GTS |
| Cooling-air flow (m³/h) | 8800 | 8800 | 11000 | 13200 |
| Cooling capacity (kW) | 18 | 25 | 32 | 37 |
| Chilled-water flow (m³/h) | 7.8 | 7.8 | 12 | 12 |
| Power supply | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz |
| Water tank capacity (L) | 130 | 130 | 190 | 190 |
| Installed power | 6 kW | 8 kW | 10 kW | 12 kW |
| Maximum current (A) | 16 | 18 | 24 | 27 |
| Cable cross-section (mm²) | 6 | 6 | 10 | 10 |
| Circuit breaker (A) | 25 | 25 | 32 | 40 |
| Pump power / head | 2.2 kW / 27.8 m | 2.2 kW / 27.8 m | 2.2 kW / 26 m | 2.2 kW / 26 m |
| Unit weight (kg) | 260 | 290 | 360 | 390 |
| Operating weight (kg) | 450 | 490 | 600 | 700 |
| Overall dimensions · L × W × H (mm) | 1300 × 750 × 1600 | 1380 × 750 × 1600 | 1500 × 860 × 1730 | 1500 × 860 × 1730 |
| Main Technical Specifications | ||||
|---|---|---|---|---|
| Model | WB-B130C-F | WB-B150C-F | WB-B190C-F | |
| Nominal class | 20 HP | B15 HP | B20 HP | |
| Cooling-air flow | m³/h | 33900 | ||
| Cooling capacity | kW | 56 | 62 | 76 |
| Chilled-water flow | m³/h | 12 | ||
| Power supply | 380V 50Hz | |||
| Water tank capacity | L | 720 | ||
| Installed power | As listed | 18.2W | 20.6 kW | 24.6 kW |
| Maximum current | A | 50 | 57 | 68 |
| Cable cross-section | mm² | 16 | ||
| Supply circuit breaker | A | 63 | 63 | 80 |
| Unit weight | kg | 810 | 900 | 950 |
| Operating weight | kg | 1570 | 1660 | 1710 |
| Overall dimensions | L × W × H (mm) | 2550 × 1050 × 2000 | ||
Legacy MLS-ZKSL GTS specifications
| Main Technical Specifications | |||
|---|---|---|---|
| MLS-ZKSL15GTS – MLS-ZKSL25GTS | |||
| Model | MLS-ZKSL15GTS | MLS-ZKSL20GTS | MLS-ZKSL25GTS |
| Cooling-air flow (m³/h) | 16500 | 22000 | 27500 |
| Cooling capacity (kW) | 48 | 65 | 75 |
| Chilled-water flow (m³/h) | 15 | 20 | 20 |
| Power supply | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz |
| Water tank capacity (L) | 230 | 270 | 320 |
| Installed power | 15 kW | 20 kW | 24 W* |
| Maximum current (A) | 39 | 46 | 54 |
| Cable cross-section (mm²) | 10 | 16 | 16 |
| Circuit breaker (A) | 63 | 63 | 80 |
| Pump power / head | 2.4 kW / 39 m | 3 kW / 32 m | 3 kW / 32 m |
| Unit weight (kg) | 550 | 630 | 810 |
| Operating weight (kg) | 900 | 970 | 1200 |
| Overall dimensions · L × W × H (mm) | 1780 × 930 × 1880 | 1850 × 1070 × 1980 | 2250 × 1050 × 2400 |
| Main Technical Specifications | ||||
|---|---|---|---|---|
| Model | WB-B95DC-F | WB-B114DC-F | WB-B150DC-F | |
| Nominal class | B25 HP | B30 HP | B40 HP | |
| Cooling-air flow | m³/h | 43400 | 45200 | 67800 |
| Cooling capacity | kW | 82 | 98 | 124 |
| Chilled-water flow | m³/h | 15 | 20 | 24 |
| Power supply | 380V 50Hz | |||
| Water tank capacity | L | 920 | 920 | 1200 |
| Installed power | As listed | 27 kW | 30 kW | 41 kW |
| Maximum current | A | 70 | 84 | 103 |
| Cable cross-section | mm² | 26 | 25 | 35 |
| Supply circuit breaker | A | 80 | 100 | 125 |
| Unit weight | kg | 1260 | 1350 | 1550 |
| Operating weight | kg | 2240 | 2330 | 2830 |
| Overall dimensions | L × W × H (mm) | 2050 × 1850 × 2050 | 3100 × 1175 × 2060 | 3400 × 1175 × 1980 |
Legacy MLS-ZKSL GTS specifications
| Main Technical Specifications | |||
|---|---|---|---|
| MLS-ZKSL30GTS – MLS-ZKSL50GTS | |||
| Model | MLS-ZKSL30GTS | MLS-ZKSL40GTS | MLS-ZKSL50GTS |
| Cooling-air flow (m³/h) | 33000 | 44000 | 55000 |
| Cooling capacity (kW) | 96 | 130 | 149 |
| Chilled-water flow (m³/h) | 24 | 35 | 45 |
| Power supply | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz |
| Water tank capacity (L) | 360 | 360 | 360 |
| Installed power | 30 kW | 40 kW | 48 kW |
| Maximum current (A) | 76 | 90 | 105 |
| Cable cross-section (mm²) | 25 | 35 | 35 |
| Circuit breaker (A) | 120 | 150 | 150 |
| Pump power / head | 4 kW / 29 m | 5.5 kW / 36 m | 7.5 kW / 39 m |
| Unit weight (kg) | 900 | 1130 | 1450 |
| Operating weight (kg) | 1250 | 1500 | 2000 |
| Overall dimensions · L × W × H (mm) | 2500 × 1150 × 2400 | 3100 × 1175 × 2060 | 3400 × 1175 × 1980 |
WB-B130C-F installed power is retained as 18.2 W in the source entry; its unit requires technical confirmation. Legacy MLS-ZKSL25GTS lists 24 W. Cooling capacity and electrical input are separate quantities. Final utility sizing follows the agreed model specification.
Air-Cooled Chilled-Water Systems
The WB-B equipment-linked chiller series supplies circulating cooling water for environmental test systems, with 12 standard models from 20 to 124 kW. Legacy MLS-ZKSL GTS specifications are retained separately below.
Stable Water Temperature
Active refrigeration provides stable water-temperature control with less dependence on ambient conditions.
Compact Installation
Choose the model by cooling load, chilled-water flow, tank capacity and installation envelope. Confirm operating conditions and utilities before final selection.
Clean Closed-Loop Circuit
The sealed circulation circuit keeps the cooling water clean and helps reduce scale formation.