Primary Applications
- Simultaneous climatic and vibration exposure of automotive, aerospace and electronic assemblies.
- Investigation of failures caused by the interaction of temperature, humidity and dynamic loading.
- Development qualification using a specified shaker spectrum and climatic program.
- Project-specific system validation with specimen fixtures and external measurement equipment.
Product Features
- Chamber volume, installation geometry and specimen fixtures engineered for the integrated test system.
- Temperature range of −70°C to +180°C and humidity range of 10–98% RH within the specified operating envelope.
- Mechanical interface, chamber movement and connection method selected for the compatible shaker.
- Remote-control capability and agreed interfaces for coordinated test operation.
- Dynamic limits follow the selected shaker, controller, mounting arrangement and specimen mass.
Applicable Test Standards
Select the exposure method, then confirm the test profile and specimen load for your application.
Combined climatic and dynamic testing with a compatible shaker, controller and specimen fixture.
Define in your protocol
- Climatic profile and vibration or shock sequence
- Specimen mass, orientation, fixtures and acceptance checks
Confirm for this chamber
- Complete chamber/shaker/controller system capability
- Interface geometry, control coordination and instrumentation
Sinusoidal vibration, subject to the integrated shaker system and fixture capability.
Define in your protocol
- Frequency range, amplitude, sweep rate and duration
- Specimen mounting, axes and functional checks
Confirm for this chamber
- Compatible shaker, controller and fixture ratings
- Total moving mass and the required climatic profile
Broadband random vibration, subject to the integrated shaker, control system and approved spectrum.
Define in your protocol
- Spectrum, frequency range, duration and test axes
- Control channels, mounting and acceptance criteria
Confirm for this chamber
- Shaker/controller capability for the specified spectrum
- Fixture response, specimen mass and climatic integration
Additional methods: IEC 60068-2-1:2025 · IEC 60068-2-2:2025 · IEC 60068-2-78:2025
Related Industry Requirements
ISO 16750-4:2023
Climatic loads for vehicle electronics
Select the climatic program for the mounting location and intended operating state. Confirm specimen supply, heat dissipation, tolerances and functional checks.
JESD22 / AEC-Q100
Device-specific methods and controlled revision
Select the applicable controlled method, exposure medium, specimen measurements and acceptance criteria. Electrical bias and complete device qualification require the specified additional apparatus and procedures.
IEC 60068 series / laboratory protocols
Document the actual exposure method
Define the relevant method or laboratory procedure, specimen load, measurement locations, calibration and repeatability criteria. Equipment selection follows the required profile and documented uncertainty.
Combined-test capability is established for the complete chamber/shaker system. Vibration and shock functions require the corresponding dynamic equipment and control system. The applicable edition, test severity, load and monitoring requirements are confirmed for the ordered configuration. Standard references do not imply complete product certification.
Technical Specifications
| Main Technical Specifications | ||
|---|---|---|
| Parameter | Unit | Project-defined configuration |
| Temperature range | °C | −70 to +180 |
| Humidity range | % RH | 10–98, within the specified operating envelope |
| Dynamic test capability | — | Defined by the compatible shaker, controller, fixture and specimen mass |
| Test profile | — | Confirm temperature levels, transitions, dwell times and cycle count. |
| Specimen & loading | — | Specify dimensions, total mass, fixtures and heat dissipation. |
| System configuration | — | Match the chamber, interfaces and protective functions to the application. |
| Site requirements | — | Confirm access, utilities, installation clearances and service conditions. |