SCI

Industrial Chillers

Air-Cooled Industrial Chillers

WB-B equipment-linked chillers with 20–124 kW cooling capacity. Legacy MLS-ZKSL GTS models are documented separately.

Send Enquiry

Primary Applications

  • Circulating cooling-water supply for compatible environmental test chambers and laboratory equipment.
  • Removal of process heat from equipment requiring a controlled water circuit.
  • Facility cooling installations where an equipment-linked air-cooled chiller is appropriate.
  • Selection of water flow, tank capacity and cooling duty for the actual heat load and ambient conditions.

Product Features

  • Current WB-B series: 12 listed models with nominal cooling capacities from 20 to 124 kW.
  • Air-cooled refrigeration with a circulating chilled-water supply.
  • Model-specific water flow, tank volume, installed power and maximum current are listed separately.
  • Closed-loop water circulation helps protect circuit cleanliness.
  • Legacy MLS-ZKSL GTS data remain separately identified and are not mixed with the WB-B series.

Applicable Safety Standards

Review the applicable equipment-safety and refrigeration requirements for the supplied chiller and its installation.

General equipment-safety reference for laboratory, measurement and control equipment.

Define in your protocol

  • Equipment scope, supply and intended installation
  • Applicable edition, risk assessment and documentation

Confirm for this chamber

  • Electrical and temperature-related protective measures
  • Required conformity assessment for the supplied equipment

Official standard reference ↗

Refrigerating-equipment safety reference, where the equipment falls within its scope.

Define in your protocol

  • Equipment classification and intended operating conditions
  • Refrigerant, installation environment and protective measures

Confirm for this chamber

  • Refrigeration circuit, pressure protection and service access
  • Required design review and conformity documentation

Official standard reference ↗

Refrigeration-system classification and safety/environmental selection criteria for project review.

Define in your protocol

  • System classification, refrigerant and occupancy category
  • Applicable published amendments and installation requirements

Confirm for this chamber

  • Refrigerant charge, room conditions and project safeguards
  • Required documentation and responsibility for the installation

Official standard reference ↗

Related Industry Requirements

These are equipment-safety and refrigeration-system references for specification review, rather than specimen environmental-test methods. Required conformity documentation and design criteria are agreed for the supplied system. The applicable edition, test severity, load and monitoring requirements are confirmed for the ordered configuration. Standard references do not imply complete product certification.

Technical Specifications

Main Technical Specifications
ModelWB-B48C-FWB-B58C-FWB-B76C-F
Nominal class6 HP7.5 HP10 HP
Cooling-air flowm³/h99001430014300
Cooling capacitykW202432
Chilled-water flowm³/h3.657.2
Power supply380V 50Hz
Water tank capacityL200360360
Installed powerAs listed6 kW8.5 kW10.5 kW
Maximum currentA1419.524.5
Cable cross-sectionmm²446
Supply circuit breakerA252532
Unit weightkg260290360
Operating weightkg480670740
Overall dimensionsL × W × H (mm)1300 × 800 × 16001550 × 900 × 16001550 × 900 × 1600
Legacy MLS-ZKSL GTS specifications
Main Technical Specifications
MLS-ZKSL02GTS – MLS-ZKSL05GTS
ModelMLS-ZKSL02GTSMLS-ZKSL03GTSMLS-ZKSL05GTS
Cooling-air flow (m³/h)220033005500
Cooling capacity (kW)6915
Chilled-water flow (m³/h)1.52.53.6
Power supply220 V / 50 Hz380 V / 50 Hz380 V / 50 Hz
Water tank capacity (L)254070
Installed power2 kW3 kW5 kW
Maximum current (A)57.214
Cable cross-section (mm²)2.52.54
Circuit breaker (A)101620
Pump power / head0.55 kW / 25 m0.75 kW / 25 m0.75 kW / 25 m
Unit weight (kg)70130190
Operating weight (kg)100200300
Overall dimensions · L × W × H (mm)690 × 790 × 1200800 × 690 × 1200960 × 790 × 1300
Main Technical Specifications
ModelWB-B88C-FWB-B95C-FWB-B114C-F
Nominal class12 HP15 HP18 HP
Cooling-air flowm³/h208002260022600
Cooling capacitykW374149
Chilled-water flowm³/h7.21010
Power supply380V 50Hz
Water tank capacityL360500500
Installed powerAs listed12 kW13 kW14.5 kW
Maximum currentA283339
Cable cross-sectionmm²6610
Supply circuit breakerA324050
Unit weightkg390550610
Operating weightkg77010801140
Overall dimensionsL × W × H (mm)1650 × 950 × 20001850 × 1050 × 20001850 × 1050 × 2000
Legacy MLS-ZKSL GTS specifications
Main Technical Specifications
MLS-ZKSL06GTS – MLS-ZKSL12GTS
ModelMLS-ZKSL06GTSMLS-ZKSL08GTSMLS-ZKSL10GTSMLS-ZKSL12GTS
Cooling-air flow (m³/h)880088001100013200
Cooling capacity (kW)18253237
Chilled-water flow (m³/h)7.87.81212
Power supply380 V / 50 Hz380 V / 50 Hz380 V / 50 Hz380 V / 50 Hz
Water tank capacity (L)130130190190
Installed power6 kW8 kW10 kW12 kW
Maximum current (A)16182427
Cable cross-section (mm²)661010
Circuit breaker (A)25253240
Pump power / head2.2 kW / 27.8 m2.2 kW / 27.8 m2.2 kW / 26 m2.2 kW / 26 m
Unit weight (kg)260290360390
Operating weight (kg)450490600700
Overall dimensions · L × W × H (mm)1300 × 750 × 16001380 × 750 × 16001500 × 860 × 17301500 × 860 × 1730
Main Technical Specifications
ModelWB-B130C-FWB-B150C-FWB-B190C-F
Nominal class20 HPB15 HPB20 HP
Cooling-air flowm³/h33900
Cooling capacitykW566276
Chilled-water flowm³/h12
Power supply380V 50Hz
Water tank capacityL720
Installed powerAs listed18.2W20.6 kW24.6 kW
Maximum currentA505768
Cable cross-sectionmm²16
Supply circuit breakerA636380
Unit weightkg810900950
Operating weightkg157016601710
Overall dimensionsL × W × H (mm)2550 × 1050 × 2000
Legacy MLS-ZKSL GTS specifications
Main Technical Specifications
MLS-ZKSL15GTS – MLS-ZKSL25GTS
ModelMLS-ZKSL15GTSMLS-ZKSL20GTSMLS-ZKSL25GTS
Cooling-air flow (m³/h)165002200027500
Cooling capacity (kW)486575
Chilled-water flow (m³/h)152020
Power supply380 V / 50 Hz380 V / 50 Hz380 V / 50 Hz
Water tank capacity (L)230270320
Installed power15 kW20 kW24 W*
Maximum current (A)394654
Cable cross-section (mm²)101616
Circuit breaker (A)636380
Pump power / head2.4 kW / 39 m3 kW / 32 m3 kW / 32 m
Unit weight (kg)550630810
Operating weight (kg)9009701200
Overall dimensions · L × W × H (mm)1780 × 930 × 18801850 × 1070 × 19802250 × 1050 × 2400
Main Technical Specifications
ModelWB-B95DC-FWB-B114DC-FWB-B150DC-F
Nominal classB25 HPB30 HPB40 HP
Cooling-air flowm³/h434004520067800
Cooling capacitykW8298124
Chilled-water flowm³/h152024
Power supply380V 50Hz
Water tank capacityL9209201200
Installed powerAs listed27 kW30 kW41 kW
Maximum currentA7084103
Cable cross-sectionmm²262535
Supply circuit breakerA80100125
Unit weightkg126013501550
Operating weightkg224023302830
Overall dimensionsL × W × H (mm)2050 × 1850 × 20503100 × 1175 × 20603400 × 1175 × 1980
Legacy MLS-ZKSL GTS specifications
Main Technical Specifications
MLS-ZKSL30GTS – MLS-ZKSL50GTS
ModelMLS-ZKSL30GTSMLS-ZKSL40GTSMLS-ZKSL50GTS
Cooling-air flow (m³/h)330004400055000
Cooling capacity (kW)96130149
Chilled-water flow (m³/h)243545
Power supply380 V / 50 Hz380 V / 50 Hz380 V / 50 Hz
Water tank capacity (L)360360360
Installed power30 kW40 kW48 kW
Maximum current (A)7690105
Cable cross-section (mm²)253535
Circuit breaker (A)120150150
Pump power / head4 kW / 29 m5.5 kW / 36 m7.5 kW / 39 m
Unit weight (kg)90011301450
Operating weight (kg)125015002000
Overall dimensions · L × W × H (mm)2500 × 1150 × 24003100 × 1175 × 20603400 × 1175 × 1980

WB-B130C-F installed power is retained as 18.2 W in the source entry; its unit requires technical confirmation. Legacy MLS-ZKSL25GTS lists 24 W. Cooling capacity and electrical input are separate quantities. Final utility sizing follows the agreed model specification.

Air-Cooled Chilled-Water Systems

The WB-B equipment-linked chiller series supplies circulating cooling water for environmental test systems, with 12 standard models from 20 to 124 kW. Legacy MLS-ZKSL GTS specifications are retained separately below.

Stable Water Temperature

Active refrigeration provides stable water-temperature control with less dependence on ambient conditions.

Compact Installation

Choose the model by cooling load, chilled-water flow, tank capacity and installation envelope. Confirm operating conditions and utilities before final selection.

Clean Closed-Loop Circuit

The sealed circulation circuit keeps the cooling water clean and helps reduce scale formation.

ENGINEERING CONSULTATION

Turn your requirement into a buildable chamber specification.

Share the essentials. Our application engineers will help define a practical, reliable system.

Application and standards reviewPractical chamber configurationInitial response within 1 business day
SCI INSTRUMENTS CO.LTD
info@scicoolings.com
PROJECT ENQUIRY

Request Engineering Consultation

Tell us the essentials. Our application engineers will help complete the specification.

Quick Chamber Selection
Select your test method, control variables and workspace. SCI will use these inputs to recommend the practical configuration.