SCI

Turntable-Compatible Test Chamber

CTT-TC Three-Axis Turntable Test Chamber

Turntable integration: extensive environmental-test integration experience with technical-team support.
Complete range: configurations for single-, dual- and three-axis turntables in multiple sizes.

Send Enquiry

Primary Applications

Compatible with multiple turntable types. Designed for aerospace, electronics and related industries to simulate environmental conditions for moving specimens and evaluate reliability and temperature performance during actual motion. Widely used for static testing and calibration of inertial components and inertial-navigation systems.

Product Features

Turntable integration: extensive environmental-test integration experience with technical-team support.
Complete range: configurations for single-, dual- and three-axis turntables in multiple sizes.
Compact and lightweight design.
Low noise and vibration: dedicated noise- and vibration-reduction treatment.
Strong performance: meets or exceeds applicable Chinese national standards and test procedures.
Custom engineering: professional support for non-standard requirements.
Multiple interfaces and drivers for secondary development.

Applicable Standards

GB/T 10589-2008 — Technical requirements for low-temperature test chambers
GB/T 10592-2008 — Technical requirements for high- and low-temperature test chambers
GJB 150A-2009 — Laboratory environmental test methods for high-reliability equipment
GJB 360B-2009 — Test methods for electronic and electrical components
JJF 1101-2003 — Calibration specification for temperature and humidity parameters of environmental testing equipment
GB/T 5170-2008 — Inspection methods for environmental testing equipment for electrical and electronic products: temperature test equipment

Main Technical Specifications
Model (Three-Axis Turntable Chamber)CTT-TC6012CTT-TC6020CTT-TC6025CTT-TC6035
Nominal VolumeL125200250365
Interior DimensionsW×H×D(mm)500×500×500600×600×600650×650×650750×650×750
Exterior DimensionsW×H×D(mm)780×920×710880×1050×810930×1100×8601030×1100×960
Temperature Range℃-60°C to +85°C (customizable)
Temperature Performance℃Fluctuation: ≤±0.5°C; uniformity: ≤2.0°C (no-load test with turntable installed, within the effective uniform zone); deviation: ≤±2.0°C
Heating / Cooling Rate℃/min-02: ≥2.0°C/min; -05: ≥5.0°C/min (no-load test with turntable installed; test range +85°C to -55°C)
Operating Noise — -02 / -05dB(A)62/6463/6765/7070/72
Installed Power — -02 / -05kW6.0/9.07.0/12.57.5/13.09.5/15.0
Equipment Weightkg160200240310
Power Supply–380 V ±10% AC, 50 Hz, 3L + N + PE; dedicated supply with separate circuit breaker and reliable grounding
Turntable Diametermm≤400≤500≤550≤650
Angular Travel–Inner axis: continuous rotation; outer axis: ±90° / ±180° / continuous rotation
Chamber-to-Turntable Connection–Bottom-frame connection / U-frame connection
Configuration — Observation WindowmmW350 × H350 mm (common to all models)
Configuration — Rotary Assembly–Compact low-friction dual-channel rotary union with anti-condensation device on the extension shaft (common to all models)
Configuration — Controller–10-inch high-brightness Chinese-language touchscreen with imported programmable controller (common to all models)
ENGINEERING CONSULTATION

Turn your requirement into a buildable chamber specification.

Share the essentials. Our application engineers will help define a practical, reliable system.

Application and standards reviewPractical chamber configurationInitial response within 1 business day
SCI INSTRUMENTS CO.LTD
info@scicoolings.com
PROJECT ENQUIRY

Request Engineering Consultation

Tell us the essentials. Our application engineers will help complete the specification.

Quick Chamber Selection