SCI

Three-Zone Cold-Storage Thermal Shock Test Chamber

CTS-TC Three-Zone Temperature Shock Test Chamber

High performance: meets or exceeds applicable Chinese national standards and test procedures.
Quiet operation: streamlined system design and noise-reduction treatment.

Send Enquiry

Primary Applications

Temperature-stress testing
Temperature screening
Temperature shock testing
Performance testing
Reliability testing

Product Features

High performance: meets or exceeds applicable Chinese national standards and test procedures.
Quiet operation: streamlined system design and noise-reduction treatment.
Severe shock capability: powerful refrigeration down to -120°C for ultra-low-temperature shock requirements.
Intelligent operation: simple controls, automatic operation and comprehensive protection.
Multi-purpose design: supports temperature shock, high-temperature and low-temperature testing.
Multiple interfaces: several data interfaces are available for secondary development.

Applicable Standards

GB/T 10592-2008 — Technical requirements for high- and low-temperature test chambers
MIL-STD-202G, Method 107G — Thermal Shock
MIL-STD-810G, Method 503.5 — Thermal Shock
GB/T 5170-2008 — Inspection methods for environmental testing equipment for electrical and electronic products: temperature test equipment
GJB 360B-2009, Method 107 — Test methods for electronic and electrical components: temperature shock
GJB 150.5A-2009 — Laboratory environmental test methods for military equipment, Part 5: Temperature shock test
GB/T 2423.22-2002 — Environmental testing for electric and electronic products, Part 2: Test methods, Test N: Change of temperature

Main Technical Specifications
Model CTS-TC□05-□F/W CTS-TC□10-□F/W CTS-TC□20-□F/W CTS-DD□30-□F/W CTS-DD□50-□F/W
Nominal Volume L 50 100 200 300 500
Interior Dimensions W×H×D(mm) 350×400×400 450×500×500 550×600×600 650×720×650 800×850×850
Exterior Dimensions W×H×D (mm) 1100×1850×1450 1200×1950×1950 1300×2050×1650 1450×2100×1750 1600×2200×2100
Temperature Range Hot zone: ambient +25°C to +200°C; cold zone: M/A and B: -75 to +120°C; C: -90 to +120°C; D: -105 to +120°C; E: -120 to +120°C
Shock Range -M:-45~+150;-A:-55~+150;-B:-65~+150;-C:-75~+150;-D:-85~+150;-E:-100~+150
Temperature Performance Fluctuation: ≤±0.5°C; temperature deviation: ≤±2.0°C
Heating / Cooling Time ℃/min Ambient to -75°C: ≤60 min; ambient to +200°C: ≤40 min
Temperature Shock Time Transfer time: ≤15 s; temperature recovery time: ≤5 min
Recovery Condition — Exposure High-temperature exposure (+150°C): 30 min; low-temperature exposure: M -45°C, A -55°C, B -65°C, C -75°C, D -85°C, E -100°C; 30 min
Recovery Condition — Specimen 2.0 kg plastic-encapsulated ICs
Operating Noise dB(A) 62 ~ 64 63 ~ 67 70 ~ 72 72 ~ 75 72 ~ 75
Installed Power kW 8.0 ~ 10.5 8.0 ~ 14.0 10.0 ~ 25.5 28.0 ~ 40.0 55.0 ~ 75.0
Equipment Weight kg 500 ~ 560 600 ~ 680 750 ~ 850 950 ~ 1050 1150 ~ 1350
Power Supply 380 V ±10% AC, 50 Hz, 3L + N + PE; dedicated supply with separate circuit breaker and reliable grounding
Configuration — Observation Window W260×H260mm W315×H315mm W345×H435mm W340×H435mm W440×H600mm
Configuration — Cable Ports One Ø80 mm cable port on the left side, supplied with one silicone plug
Configuration — Specimen Shelves Height-adjustable stainless steel; quantity: 1
Configuration — Controller High-brightness Chinese-language touchscreen with imported programmable controller
Configuration — Drive Method Bidirectional pneumatic drive; stable and reliable
ENGINEERING CONSULTATION

Turn your requirement into a buildable chamber specification.

Share the essentials. Our application engineers will help define a practical, reliable system.

Application and standards reviewPractical chamber configurationInitial response within 1 business day
SCI INSTRUMENTS CO.LTD
info@scicoolings.com
PROJECT ENQUIRY

Request Engineering Consultation

Tell us the essentials. Our application engineers will help complete the specification.