Temperature & Humidity Test Chambers



Choose the correct low-temperature platform and workspace volume, then review verified dimensions, installation access and lab planning requirements before requesting a quotation.
Choose Your Standard Model
−40°C STANDARD SERIES
MODEL | VOLUME | WORKSPACE (D×W×H) | EXTERNAL (D×W×H) | WINDOW
CTE/H-SG4008C-02F | 80 L | 400×400×500 mm | 1310×600×1700 mm | 250×300 mm
CTE/H-SG4015C-02F | 150 L | 500×500×600 mm | 1510×700×1830 mm | 300×350 mm
CTE/H-SG4031C-02F | 315 L | 600×700×750 mm | 1560×900×1730 mm | 400×500 mm
CTE/H-SG4050C-02F | 504 L | 700×800×900 mm | 1550×1000×1880 mm | 400×500 mm
CTE/H-SG40100C-02F | 1000 L | 1000×1000×1000 mm | 1850×1200×1980 mm | 450×550 mm
−70°C STANDARD SERIES
MODEL | VOLUME | WORKSPACE (D×W×H) | EXTERNAL (D×W×H) | WINDOW
CTE/H-SG7008C-02F | 80 L | 400×400×500 mm | 1310×600×1700 mm | 300×350 mm
CTE/H-SG7015C-02F | 150 L | 500×500×600 mm | 1510×700×1830 mm | 300×350 mm
CTE/H-SG7031C-02F | 315 L | 600×700×750 mm | 1560×900×1730 mm | 400×500 mm
CTE/H-SG7050C-02F | 504 L | 700×800×900 mm | 1550×1000×1880 mm | 400×500 mm
CTE/H-SG70100C-02F | 1000 L | 1000×1000×1000 mm | 1870×1200×1990 mm | 450×550 mm
Select the low-temperature platform first. Every series below is available in 80, 150, 315, 504 and 1,000 L standard workspace volumes. Dimensions are W × D × H in millimetres.
Plan the Chamber Inside Your Real Space
Use the chamber configurator to define the room and place equipment with real installation clearances. The planning brief can include:
• Country / region installation preset and local compliance pathway
• Room width, depth and ceiling height
• Door position, door swing and equipment access route
• Ambient temperature and heat-rejection conditions
• Building floor and delivery route
• Floor load and point-load verification
• Front, side, rear and overhead service clearance
• Utilities, drainage, ventilation and fire-strategy notes
The generated layout can be sent with your enquiry so SCI engineers see the same room plan you created.
Frequently Asked Questions
Which low-temperature platform should I choose?
Choose −40°C when your test method does not require exposure below that point. Choose −70°C for deeper low-temperature testing or when your internal standard explicitly calls for it. Final selection should also consider specimen mass, heat load, pull-down requirement and recovery time.
Why is 408 L not included in this standard range?
The supplied standard product sheet assigns 408 L to the rapid-temperature-change product platforms. The standard CTH-02F range uses 80, 150, 315, 504 and 1,000 L. This page follows the new authoritative model table so quotation and engineering data stay aligned.
Which site conditions must be confirmed before ordering?
Confirm room temperature, altitude, supply voltage and frequency, floor level, floor load, delivery-route dimensions, door swing, service clearances, ventilation, drainage and utility connections. Final quantities and installation approval must be based on the approved outline drawing and the actual site survey.
Send Your Selected Model and Site Plan to SCI
Include your preferred model, application, required temperature and humidity range, specimen heat load, room dimensions, floor information and target installation date. The inquiry uses the same Elementor quote experience as the rest of the SCI website.
Continue Your Engineering Review
Use these related SCI pages to verify capabilities, installation support and application evidence before final selection.